<LOGO>
FM Transmitter Measurement Report
Created: 2025-10-02 01-29-47
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
100.70 MHz 4/5, 58 dBuV N.DAME
Pilot RDS Phase Difference
6.8 kHz 3.4 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
16 kHz 88 kHz 4513 91,7350
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
4,3 dBr 4,96 dBr 6,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" N.DAME " FE32 0 (No PTY) 0 0 1 2 1:29, 2.10.2025
RT
"La Vie prend un sens. J'ecoute, je donne. radionotredame.com "
AF EON
90.7, 100.7 MHz -
FM Scope Station: 100.70 MHz, signal: 4/5 (59 dBuV) Max at: 88 kHz MIN: 16 kHz % above 75 kHz: 91,7350 Acquired: 2025/10/02 1:28:43 Total samples: 4513 Equivalent time: 0:03:45 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400